INSTALLATION, OPERATING AND MAINTENANCE MANUAL
FOR REFRIGERATED BASE UNITS
1. WARNINGS
Read this manual carefully
before commencing installation.
The manual has been devised to furnish the user with all the information required to operate the equipment safely, from its
transportation right through to scrapping.
The manual must be looked after carefully so that it is available for future reference. In the event the equipment is sold, the manual
must also be handed over to the new user.
In order to use the equipment correctly:
• Do not tamper with the safety devices;
• Use the equipment only for the purpose for which it was specifically designed;
• Keep unauthorized personnel away from the equipment;
• Have maintenance performed by qualified personnel only;
• Switch off the equipment in the event of a fault or irregular operation;
• Only use spare parts supplied or indicated by the Manufacturer.
ATTENTION: ONLY QUALIFIED ELECTRICIANS ARE AUTHORIZED TO ACCESS THE MAIN CONTROL BOARD AND ANY
OTHER ELECTRICAL PARTS, WHETHER FOR INSTALLATION OR MAINTENANCE PURPOSES.
The Manufacturer declines all responsibility for damage to property or bodily injury as a result of non-compliance with the instructions
and warnings contained herein.
If in any doubt, and whenever the need arises, contact the DEALER.
2. INTRODUCTION
The equipment conforms to the EEC Directives 2004/108/CE e 2006/95/CE.
In addition, the following standards have also been applied: CEI EN 55014, EN 61000-3-2, EN 61000-3-3, EN 60335.1 and EN
60335.2.89.
3. DESCRIPTION OF THE EQUIPMENT
Our REFRIGERATED BASE UNITS are made up of refrigerated cabinet with predisposition for top. The refrigerating unit housed in the
right part with the control panel. The REFRIGERATED BASE UNITS are 1200 mm or 1600mm long and 600 or 700 mm deep. (see
table A)
4. TRANSPORTATION AND HANDLING
If the equipment is transported on a pallet, it must be unloaded using a lift truck or other appropriate lifting means operated by trained
personnel. The maximum weight is given in Table A.
Manoeuvring errors might cause injury as a result of crushing. Any blows to the surfaces of the equipment will result in immediate
damage.
During this phase, anyone not directly involved in the operation must not be allowed to remain in the area.
The personnel handling the equipment must wear appropriate personal safety gear (e.g. work gloves, safety boots).
5. OPERATING CONDITIONS AND TECHNICAL FEATURES
Our REFRIGERATED BASE UNITS have been designed solely for the preservation and display of cold foods and drinks at the
temperatures given in Table A, for use in rooms used for group catering. Any other use shall be considered improper.
The REFRIGERATED BASE UNITS are available in the configurations featured in Table A.
5.1 Commands and controls
The equipment is controlled by the control board to be found in the compressor compartment, normally on the right.
5.2 Protection and safety devices
See alarms under point 7.3.
6. INSTALLATION
6.1 Positioning
Place the equipment in a ventilated room, away from heat sources, so as to assure a sufficient supply of fresh air in the area taken up
by the compressor. The REFRIGERATED BASE UNIT has been designed for use in a room with a maximum temperature of 32°C.
If the room temperature is higher, this may also have an effect on the temperature inside and may result in malfunctioning or damage
to the equipment.
The equipment is standard equipped with adjustable feet to obtain the desired height and compensate for any unevenness or slope of
the floor. Once installation is complete, the protective film can be removed. This operation should be performed very slowly to prevent
the glue remaining attached to the surfaces. If this happens, use kerosene or petrol to remove it.
6.2 Electrical connections
Connections must be made in accordance with the local standards in force. The equipment's electric circuit is designed to work with a
single-phase supply voltage of 230 Volts and a frequency of 50 Hz.
Electrical connection is made by connecting a cable to the terminal board, which is underneath the control panel of the unit (at right, on
the inner side).
The units electrical supply system must feature an appropriately sized automatic omnipolar circuit breaker upstream that assures a gap
between the contacts of at least 3mm. There must not be any breaks in the earth cable.