►►►14. PREVENTIVE MAINTENANCE SCHEDULE
COMPONENT MAINTENANCE FREQUENCY MAINTENANCE PROCEDURE
Filters Clean or replace once a year or as required
(check integrity)
Clean the lters (SEE PAR. “CLEANING THE
FILTERS”)
Fuel pump lter Clean or replace once a year or as required
(check integrity)
Contact the support centre
Electrodes Clean as required Contact the support centre
Fan Clean as required Contact the support centre
Combustion chamber Clean as required Contact the support centre
►►►15. TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION
The heater does
not start or does not
remain on
1. Heater in stand-by
2. No power supply or inadequate
operating voltage
3. Interrupted power cable
4. Electronics need to be reset or
are faulty
5. Incorrect setting of the room
thermostat (if applicable)
6. No fuel
7. Foreign substances in the fuel
circuit
8. Temperature set on the room
thermostat too high
9. Electronics blocked
1. Press the button “ON/OFF“ / “VENTILATION” (A/B Pic. 3)
2a. Plug the power cable correctly into the mains socket (Pic. 5)
2b. Check the correct voltage of your system
2c. Electrically supply the heater only with electric extension
cords of a suitable cross-section, properly earthed
3. Contact the support centre
4a. Reset the heater (SEE PAR. “RESETTING THE HEATER”)
4b. Contact the support centre
5. Set the room thermostat to a temperature higher than the
temperature of the working environment (Pic. 6)
6. Refuel and, if necessary, reset the heater (SEE PAR.
“RESETTING THE HEATER”)
7a. Empty and ll the tank with clean fuel
7b. Clean the lters (SEE PAR. “CLEANING THE FILTERS”)
7c. Contact the support centre
8. Lower the set temperature of the room thermostat
9. Reset the electronics (SEE PAR. “RESETTING THE
HEATER”)
The heater generates
smoke during
operation
1. Foreign substances in the fuel
circuit
2. Obstruction of inlet air vent
1a. Empty and ll the tank with clean fuel
1b. Clean the lters (SEE PAR. “CLEANING THE FILTERS”)
1c. Contact the support centre
2. Remove all possible obstructions from the air vent
The heater does not
switch o
1. Electronics are faulty 1. Contact the support centre
Fan runs abnormally
or rotates in the
opposite direction
1. Incorrect electrical connection 1. Contact the support centre