WALK-IN MAINTENANCE
EL
ECTRICAL CONNECTION
Referring to the wiring diagram in the "Electrical Connections" section of this manual, connect the heater wire leads
as shown. If short lengths of the lead wires were left as indicators, connect the replacement heater leads to those
points of connection and discard the short indicator lengths.
NO
TE: If one of the heater leads connects to another wire through a wire connector, obtain a properly sized, twist-
on wire connector for this purpose.
Replace the pilot light and switch in the switch box and attach the switch cover to complete the job. Energize the
walk-in cooler to resume operation.
PAN
EL CLEANING AND MAINTENANCE RECOMMENDATIONS
During uncrating, handling and installation, the panel surfaces of your walk-in cooler or freezer may have become
stained or dirty. Cleaning all metal type surfaces, door trim and gaskets can be performed with a mild detergent and
hot water. It is important that you remove all excess soap and dry the surfaces
thoroughly. Never, under any circumstances, use an abrasive or alkaline solution.
Occasionally it may become necessary to clean the interior surface for sanitary purposes. A mild solution of baking
soda and warm water will tend to impart a clean, sweet smell to the interior should odors occur from spillage or
container breakage. Never leave standing water inside the walk-in cooler or freezer.
Warning: Walk-in floor must be kept free of any liquids, food particles or any items that could cause a slip hazard.
Spilled liquids, food particles or any moisture on the walk-in floor can cause the floor to become slippery. Always
keep the floor surface clean and dry.
• Inspect non-skid floor strips on ramps and floor surfaces and replace if worn.
• Inspect refrigeration system, door gaskets and hardware for proper operation to prevent moisture on walk-in
floor, ceiling or walls.
• Avoid leaving entry doors open for more than five minutes, which can cause a film of ice or moisture to form on
floor, ceiling and wall surfaces due to the excessive condensation of warm moist air entering the walk-in. Vinyl strip
curtains can be used to reduce the amount of warm moist air entering the walk-in.