WALK-IN INSTALLATION
IMPORTANT! When all field wired connections are completed in the junction box located on top of the ceiling
section, be sure to THOROUGHLY SEAL the conduit fitting through which the wiring projects into the junction box.
The silicone sealant provided is well suited for this purpose. Failure to do so will permit moisture to form within the
junction box and electrical fixture(s) and potentially cause a short.
POSITIONING THE THERMOMETER SENSING BULB
For convenient monitoring of the temperature of the storage compartment of this walk-in, a remote reading
thermometer has been installed in the door section at about eye level. It is a flush panel mount with an LED readout.
For optimum accuracy, the sensing bulb must be exposed to the air that is being
monitored. Make certain that the sensing bulb is not positioned near the interior light
or any other heat producing device, nor should it be located where stored products
shield the sensing bulb from the circulating air
pattern within the walk-in. The long sensing lead is more than adequate to provide an
ideal sensing bulb placement on the inside surface of the door section or an adjacent
wall or corner panel. When the location is finalized, an adhesive backed, plastic clip is
used to secure the sensing bulb to that surface.
To prevent possible damage to the door opening heater and/or to the protective globe
over the interior light, DO NOT energize the door/door section until the interior
temperature has been reduced to the normal operating range by refrigeration. A
caution label is affixed to the door section near the vapor proof light to serve as a
reminder.
PRESSURE RELIEF PORT
If a pressure relief port is supplied, connect it to a 115/60/1 VAC power supply.
WIRING DIAGRAM: A wiring diagram showing the electrical components contained in
the door/door section circuitry involved as shown. Always refer to the wiring diagram if
it becomes necessary to replace any of the components.