14 Martin
®
P3 PowerPort 2000 and 500 IP Safety, Installation and User Manual
Side panel
The P3 PowerPort 500 IP Rental has a pressure equalization valve on the side of the device (see
illustration). Check this valve visually from time to time. If it appears to be dirty, consult Martin Service for
possible replacement
Installing
Read the ‘Safety Information’ section starting on page 5 before installing, applying power to or operating
the device.
The P3 PowerPort 500 IP Rental is designed to be installed in a 19-inch rack, on a rigging truss or on a
flat surface in any orientation.
Rack mounting
To mount one single P3 PowerPort 500 IP Rental in a 19-inch rack:
1. Fasten one short rack ear (supplied) and one long rack ear (supplied) to the front of the device using
the supplied screws. Do not fasten the supplied safety cable attachment bracket to the device.
2. Fasten the device into the rack. Bear in mind the need for good ventilation and the possible need for
fan cooling.
To mount two P3 PowerPort 500 IP Rental
devices side-by-side in a 19-inch rack:
1. See illustrations on right. Fasten the two
devices together by fastening the two
supplied coupling plates to the devices,
one plate on the front and one plate on
the rear, using the supplied screws.
2. Fasten the two supplied short rack
mounting ears to the devices using the
supplied screws. Note that you can
rackmount the devices with the
connections panel at the front or at the
rear of the rack, but if you mount them at
the front the status LEDs and Test/Reset
button will be less accessible. Do not
fasten the supplied safety cable
attachment bracket to the devices.
3. Fasten the two devices into the rack.
Bear in mind the need for good
ventilation and the possible need for fan
cooling.
Truss mounting
When installing the P3 PowerPort 500 IP Rental on a rigging truss, use half-coupler type rigging clamps
(see Figure 1 on page 12) that completely encircle the truss chord. Rigging clamps must be in perfect
condition and approved for the weight that they will support.
You can install the P3 PowerPort 500 IP Rental on a rigging truss either mounted horizontally or hanging
vertically.
Pressure
equalization valve
Rigging
bracket
Short rack
mounting ear
Coupling plate for side-
by-side rack mounting