Operation
Whenever AC power is applied to the fixture, it reboots its software and resets all effects to their home
positions. Reset is available when fixture temperature is above -10° C (14° F).
Operating temperature precautions
Do not operate the fixture in an ambient temperature that exceeds the specified maximum of 45° C
(113° F). Fixtures have an internal thermal sensor. If the sensor measures excessive temperature, a
thermal protection system reduces light output. If the temperature is dangerously high, a thermal
cutout shuts down the fixture. The fixture will not function normally again until the temperature has
fallen to a safe level.
Do not operate the fixture in an ambient temperature below -30° C (-22° F). For instant wake-up with
no warm-up mode, we recommend that you keep power applied constantly in ambient temperatures
below 0° C (32° F).
Cold starting
If the fixture detects an internal temperature below -10° C (14° F) when it is powered on, it
automatically activates Cold Start mode. In this mode, DMX control is disabled but RDM functionality
remains normal. The LEDs light up, the heating plate activates, the LED cooling fan is disabled and
the three internal cooling fans run at full speed. The color wheel rotates slowly and the zoom and
focus motors move back and forth. All motors will reset every 5 minutes.
Once the fixture detects that its internal temperature has risen to above -10° C, it exits Cold Start
mode. It performs a full motor reset, and DMX control returns to normal.
Cleaning
Excessive dirt buildup causes overheating and may lead to damage that is not covered by the product
warranty. Clean the product at regular intervals (see the Maintenance chapter at the end of this
manual).
Condensation and pressure relief valve
A valve with a gas-permeable membrane in the base of the product equalizes pressure by allowing air
to pass through it when the product heats up and cools down, but at the same time it acts as a barrier
to water in liquid form. This valve requires maintenance see the Maintenance chapter later in this
User Manual for details.
Under certain conditions, condensation may become visible inside the front glass. This is normal and
harmless. The fixture gradually expels condensation via its pressure relief valve. If excess
condensation is present inside the fixture, we recommend that you open the effects compartment
cover in dry conditions, run the fixture to warm it up, replace the anti-humidity bag in the cover and re-
install the cover. The procedure for doing this is described in the Safety and Installation Manual
included at the end of this User Manual.