Engineer 418 & 818 User Manual  Page 76 
To recall this preset we would now do the following: 
  Open a connection to the device 
  Set the RTS pen 
  Wait for 10 ms 
  Send package 254 14 0 0 255 12 
  Reset the RTS pin 
Setting master- and zone volumes 
Zone volumes can also be set using their respective index. As with the preset recalls, you can determine which 
zone corresponds to a certain index from the Engineer control software: 
In this example zone 1 is named “Dance Floor” and has outputs 1, 2 and 3 assigned to it which are labelled 
“Sub”, “WT3 L” and “WT3 R”. Zones are indexed from 136: Zone 1 corresponds to index 136, zone 8 
corresponds to index 144. The master volume's index is 84. These indices are referred to as “node-index”. 
Gain values in the Engineer are indexed from -45 dB to +15 dB in steps of a quarter of a dB: 
Index  0  1  2  ....  180  ...  239  240 
Gain [dB]  -45.00  -44.75  -44.50    0 dB    +14.75  +15.00 