Marshall CV630-WI handleiding
Handleiding
Je bekijkt pagina 18 van 24

www.marshall -usa.com
33 34
CV630-BI/WI/ND3/ND3W
User Manual
SRT
The port number must be set in the range above 1024 with a maximum value of
9999
<Remark> The following port is used by the camera. Setting of the port may not
connect correctly
1935,8554,8555,8556,8557
Delay time is for 20 to 8000 microseconds. The default value is 120 microseconds
Stream1/ 2: Please refer to 6.2.3.1 Streaming parameter setting table below for
relevant settings
6.2.3.1 Streaming parameter setting
Function Streaming 1 Streaming 2 Streaming 3
Encode Format H.265 H.264
Resolution 4K 1080p / 720p /1080i 4K
Frame Rate Setting according to the supported resolution
Bit Rate(kbps)
2,000~20,0
00
2,000~20,000 2,000~20,000 512~5,000
7,000 7,000 7,000 1,000
Rate Control
CBR / VBR
IP Ratio
Setting according to the supported resolution
SRT
The port number must be set in the range above 1024 with a maximum value of
9999
<Remark> The following port is used by the camera. Setting of the port may not
connect correctly
1935,8554,8555,8556,8557
Delay time is for 20 to 8000 microseconds. The default value is 120 microseconds
Stream1/ 2: Please refer to 6.2.3.1 Streaming parameter setting table below for
relevant settings
6.2.3.1 Streaming parameter setting
Function Streaming 1 Streaming 2 Streaming 3
Encode Format H.265 H.264
Resolution 4K 1080p / 720p /1080i 4K
Frame Rate Setting according to the supported resolution
Bit Rate(kbps)
2,000~20,0
00
2,000~20,000 2,000~20,000 512~5,000
7,000 7,000 7,000 1,000
Rate Control
CBR / VBR
IP Ratio
Setting according to the supported resolution
6.2.3 Stream – NDI
For CV630-ND3/ND3W only; the setting is available when NDI|HX is set to HX2/HX3
No Item Function Descriptions
1 Camera ID/ Location Displaying ID/location according to [System] > [Device] setting content
2 Group Name
The group name can be modified here and set with Access Manager -
Receive in NDI Tool
If no group is assigned, the machine belongs to Public. As the
default of Access Manager includes Public, Studio Monitor can
discover this machine
If a group is assigned, but this group is not added into Access
Manager, Studio Monitor cannot discover this machine
If a group is assigned and this group is added into Access
Manager, Studio Monitor can discover this machine
<Remar
k> The name can contain commas (,) to distinguish
different groups
Example: default, 123, abc means this machine
belongs to three groups at the same time (default/ 123/
abc)
3 NDI|HX
Set NDI HX 2/ HX3/ Off
Off: Support RTSP/ RTMP/ RTMPS/ MPEG-TS/ SRT, and ONVIF
can find devices but cannot be used with NDI Tool
HX2: Support HX2
HX3: Support HX3
< Remark > HX3 only supports 1080p 60/59.94/50 resolutions
<Remark> ONVIF cannot find devices, and RTSP/ RTMP/ RTMPS/
MPEG-TS/ SRT streams cannot be used when HX2/ HX3 on.
www.marshall-usa.com
Bekijk gratis de handleiding van Marshall CV630-WI, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Marshall |
Model | CV630-WI |
Categorie | Bewakingscamera |
Taal | Nederlands |
Grootte | 9948 MB |