D-3
MAINTENANCE
Replacement Steps:
See Figure D.1 for steps 1-9.
1. Disconnect the extraction fan(s) from the input power.
2. Loosen latches (A) and remove the lter cover (B).
3. Unscrew the knurled nut (C) and remove the lter cover plate (D).
4. Lift the LongLife lter cartridge (E) up and out of the ltration
unit.
5. Remove the prelter (F).
6. If required by federal, state and/or local regulations and
guidelines, conceal prelter in appropriate bag, e.g. plastic bag.
7. Clean the lter compartment with an industrial vacuum cleaner
that meets OSHA guidelines for Cr6 housekeeping.
8. Install a new prelter.
9. Replace the dismounted parts in reverse order.
ACTIVATED CARBON FILTER (OPTION)
Replace the Activated Carbon Filter:
• When detecting odors and smells; or
• When it has been damaged.
Replacement Steps:
See Figure D.1 for steps 1-6.
1. Disconnect the extraction fan(s) from the input power.
2. Loosen latches (A) and remove the lter cover (B).
3. Unscrew the knurled nut (C) and remove the lter cover plate (D).
4. Remove the Activated Carbon Filter from the LongLife lter
cartridge.
5. Install a new Activated Carbon Filter.
6. Replace the dismounted parts in reverse order
B
A
E
F
A
D
C
FIGURE D.1