D-3
MAINTENANCE
Replacement Steps:
See Figure D.1 for steps 1-9.
1. Disconnect the extraction fan(s) from the input power.
2. Loosen latches (A) and remove the lter cover (B).
3. Unscrew the knurled nut (C) and remove the lter cover plate (D).
4. Lift the LongLife lter cartridge (E) up and out of the ltration
unit.
5. Remove the prelter (F).
6. If required by federal, state and/or local regulations and
guidelines, conceal prelter in appropriate bag, e.g. plastic bag.
7. Clean the lter compartment with an industrial vacuum cleaner
that meets OSHA guidelines for Cr6 housekeeping.
8. Install a new prelter.
9. Replace the dismounted parts in reverse order.
ACTIVATED CARBON FILTER (OPTION)
Replace the Activated Carbon Filter:
When detecting odors and smells; or
When it has been damaged.
Replacement Steps:
See Figure D.1 for steps 1-6.
1. Disconnect the extraction fan(s) from the input power.
2. Loosen latches (A) and remove the lter cover (B).
3. Unscrew the knurled nut (C) and remove the lter cover plate (D).
4. Remove the Activated Carbon Filter from the LongLife lter
cartridge.
5. Install a new Activated Carbon Filter.
6. Replace the dismounted parts in reverse order
B
A
E
F
A
D
C