D-2
MAINTENANCE
FILTER REPLACEMENT
Take necessary precautions so that you
and your fellow workers are not
overexposed to particulate. Wear suitable
personal protection equipment, such as
gloves, respirator, eye glass and protective
clothing when disposing of the lter and particulate.
Check with local waste management or local agency(ies)
for assistance in the disposal of lter. If lter has
collected certain types of particulate which local
agencies dene as hazardous waste, lter may be
classied as hazardous waste and will need to be
disposed in accordance with federal, state and local
regulations - which could vary from state to state, and
between local municipalities within the state.
LONGLIFE FILTER CARTRIDGE
Replace the LongLife lter cartridge:
when the Filter Maintenance Indicator (See Figure B.1) shows
that the lter cartridge is saturated or clogged; or
when the airow is reduced to the point that extraction
performance is no longer satisfactory; or
when it has been damaged.
Replacement Steps:
See Figure D.1 for steps 1-8.
1. Disconnect the extraction fan(s) from the input power.
2. Loosen latches (A) and remove the lter cover (B).
3. Unscrew the knurled nut (C) and remove the lter cover plate (D).
4. Lift the LongLife lter cartridge (E) up and out of the ltration
unit. It is not necessary to remove the prelter (F) unless it needs
replacement.
5. If required by federal, state and/or local regulations and
guidelines, conceal lter in appropriate bag, e.g. plastic bag.
6. Clean the prelter and lter compartment with an industrial
vacuum cleaner that meets OSHA guidelines for Cr6 house-
keeping.
7. Install a new LongLife lter cartridge.
8. Replace the dismounted parts in reverse order.
PREFILTER
Replace the prelter:
when it is saturated or clogged and can’t be cleaned using a
vacuum cleaner; or
when it has been damaged.
NOTE: In case the prelter has been damaged, it is recommended
to also replace the LongLife lter cartridge.
WARNING
TABLE D.1 – PERIODIC MAINTENANCE
COMPONENT ACTION
EVERY
MONTH
EVERY 6
MONTHS
Filter Maintenance Indicator
Unless LongLife lter cartridge is clean, check if indicator moves upwards upon
starting fan(s). If not, See Troubleshooting Section.
X [*]
Prelter, LongLife lter cartridge
and optional Activated Carbon
Filter
Check for damage, clogging and saturation. If damaged, clogged or saturated, See
Filter Replacement.
X
Filter cover and bottom housing
Clean inside with an industrial vacuum cleaner that meets OSHA guidelines for Cr6
housekeeping and remove the dust from the lter compartment.
X
Clean outside with a mild detergent. X [*]
Check for cracks or holes. If damaged, See Troubleshooting Section. X [*]
prelter
Replace every lter change or clean with an industrial vacuum cleaner that meets
OSHA guidelines for Cr6 housekeeping.
X
Connection hose(s) Check for cracks, holes or deformities. If damaged, See Troubleshooting Section. X [*]
Non-return valves (Dual Arm
versions only)
Check buttery aps for free movement, deformities and particulate build-up or
debris. If damaged, See Troubleshooting Section.
X