Lincoln Electric Prism Wall Mount handleiding
Handleiding
Je bekijkt pagina 17 van 36

B-2
OPERATION
Only use the product for the welding
processes described in the General
Description. Avoid using the product for
extracting and/or ltering fumes and gases which are
released during the following (welding) processes:
• oxy-fuel cutting
• aluminum laser cutting
• oil-treated metal
• arc-air gouging
• oil mist
• paint mist
• heavy oil mist in welding fume
• hot gases (more than 40°C/100°F continuously)
• aggressive gases (e.g. from acids)
• plasma cutting
• grinding aluminum and magnesium
• ame spraying
• extraction of cement, saw dust, wood dust etc.
• sucking cigarettes, cigars, oiled tissues and other
burning particles, objects and acids
• in all situations where explosions can occur
(This list is not comprehensive.)
If the product is used in above situations it could result in
potential re hazard, non-compliance with local
regulations and reduction in product performance and
life.
USERS
This product should only be used by authorized, trained and
qualied users.
INTENDED USE
The product has been designed exclusively for ltering fume
which is released during common weld processes. Using the
product for other purposes is considered contrary to its intended
use. Lincoln Electric accepts no liability for any damage resulting
from such use. Only use the product in mechanically sound
condition in accordance with its intended use and the instructions
set forth in the user manual.
MODIFICATIONS
Modications of this product, other than those specied in this
manual, are not allowed. Modications will void the product
warranty.
OPERATION
The operation description below applies to all versions of the base
unit. The air which contains welding fume is captured, extracted
and ltered, in which the ltered air can be either recirculated or
exhausted.
• First, the welding fume is extracted through one or two
adjustable fume extraction arm(s) by one or two external
extraction fan(s).
• Second, the fan unit(s) exhaust(s) the welding fume via a hose or
duct into the Prism Wall Mount lter unit.
• Third, as the welding fume enters the Prism Wall Mount unit, it
passes through the prelter in the center of the LongLife lter
cartridge. The prelter separates larger particles, debris and
sparks prior to the welding fume entering the LongLife lter.
• Fourth, the welding fume passes through the LongLife lter
cartridge (stabilized).
• Fifth, after passing through the LongLife lter, the ltered air
exits the Prism Wall Mount via the outlet opening(s) at top of unit.
If desired, and local or federal regulations permit, ltered air can
be recirculated back into work environment or exhausted outside
of building.
WARNING