32 Document #: LIN_EOGO_IOM_24APERION_4605890_Rev1 - 01/24
Troubleshooting Section 5
User Interface
(Touchscreen)
Alarm Message
Cause Correction
Applicable
for Electric
Units
Applicable
for Electric
Units
“Upper Blower OC: 0x03”
--OR--
“Lower Blower OC: 0x03”
Upper or lower motor current
overload
Check door is closed correctly. Check
latches and hinges
XX
Make sure fingers are installed
correctly
Turn OFF the unit using the power
switch, turn the unit back ON after 20
seconds. If the condition persists call
for service.
“Upper Blower UV: 0x04”
--OR--
“Lower Blower UV: 0x04”
Upper or lower drive
undervoltage
(line voltage less than 75VAC)
Facility may be experiencing brownout,
wait for it to pass. If the condition
persists, call for service.
X
Upper or lower drive
undervoltage
(line voltage less than 151VAC)
X
“Upper Blower OV: 0x06”
--OR--
“Lower Blower OV: 0x06”
Upper or lower drive
overvoltage
(line voltage greater than
141VAC)
Turn OFF the unit using the power
switch, turn the unit back ON after 20
seconds. If the condition persists call
for service.
X
Upper or lower drive
overvoltage
(line voltage greater than
283VAC)
X
“Upper Blower
Communication Error
--OR-- “Lower Blower
Communication Error
Modbus communication error
Turn OFF the unit using the power
switch, turn the unit back ON after 20
seconds. If the condition persists call
for service.
XX
“Upper Blower Motor
Phase loss (0 RPM)”
--OR-- “Lower Blower
Motor Phase loss (0
RPM)”
Upper or lower motor phase
disconnected
Turn OFF the unit using the power
switch, turn the unit back ON after 20
seconds. If the condition persists call
for service.
XX
“Upper Blower Motor
Failure (Low RPM)”
--OR-- “Lower Blower
Motor Failure (Low
RPM)”
Upper or lower motor not
moving
Turn OFF the unit using the power
switch, turn the unit back ON after 20
seconds. If the condition persists, call
for service.
XX
Thermal Error”
High temperature limit tripped
in component compartment or
cooking cavity, or combustion
blower fan failure (only in gas
units), resulting in no heat
condition
Turn the power switch OFF and wait
for the machine to cooldown (this may
take upwards of one hour). Reset the
high limit capillary thermostat located
on the machine rear panel. Turn the
power switch ON. If the condition
persists, call for service.
XX
“IO Software Inapplicable
(Minimum 111)”
Incorrect IO software revision
installed
Call for service X X