8.4 Replacing appliance battery
In the event of a power failure, the appliance battery is used
to record temperature history, alarm and service messages
and to show the alarm messages on the display for approx‐
imately 12 hours. During initial commissioning, the battery
may take up to 24 hours to charge and be in proper working
order.
A replacement battery is available from customer service
(see 9.3 Customer Service) .
8.4.1 Replacing battery
WARNING
Short-circuit hazard due to live parts!
Electric shock or damage to the electronics.
u
Switch off the appliance.
u
Pull out mains plug or switch off fuse.
Fig. 189
u
Unscrew the screws and remove the cover on the back of
the appliance Fig. 189(1).
u
Disconnect and remove the battery Fig. 189(2).
u
Install replacement battery.
u
Reconnect mains power cable.
Note
u
The battery must be sent for separate waste treatment
for batteries and must be disposed of in an expert and
proper manner in accordance with the regulations and
laws which apply locally. Do not damage or short circuit
the battery!
9 Customer help
9.1 Technical specifications
Temperature range
Cooling +3°C to +16°C
Maximum load per shelf
A)
Appliance width 600mm 750mm
Grid shelves 45 kg 60 kg
Glass shelf 40 kg 40 kg
Wooden shelf 45 kg 60 kg
Drawer 20 kg 20 kg
A)
Heavier loads may result in a slight bending of the
shelves.
Maximum total load and net weight
Model (see 4.2 Appliance
dimensions)
Maximum total
load
Net weight
SRTvh 1501
SRTvh 1511
180 kg 37 kg
43 kg
Net capacity
See net capacity on the type plate. (see 1.2 Overview of
the appliance and equipment)
Lighting*
Energy efficiency class
A)
*
Light source*
This product contains one or more energy
efficiency class G light sources
LED
A)
The appliance may contain light sources with different
energy efficiency classes. The lowest energy efficiency
class is indicated.
WLAN frequency specification*
Frequency band 2.4GHz
Maximum radiated power <100 mW
Purpose of the wireless
equipment
Integration in the local WiFi
network for data communi‐
cation
Set-up conditions
Degrees of pollution (surrounding
the appliance)
PD2
Ambient temperature +10°C to +35°C
Maximum relative ambient moisture 75%, not condensing
Maximum operating elevation
(metres above sea level)
2000m
1500m(glass door)
Electrical values
Nominal voltage 220-240 V~
Frequency 50/60Hz
Connected load 2,0A
Maximum mains fluctuation +/-10%
Overvoltage categories II
Data as per DIN 13277 measured at a reference ambient
temperature of +25°C
Model
SRTvh
Energy
consump‐
tion (kWh/
24h)
Tempera‐
ture rise
during
mains
failure
(min)
Tempera‐
ture
homoge‐
neity (°K)
Temperature
constancy
(°K)
1501 0.32
108
A)
1.1
B)
1.8
B)
1511 0.41
77
A)
0.9
B)
2.3
B)
A)
Erwärmung Referenzkörper: von +5 °C auf +10 °C / Refer‐
enzkörper: 50 ml Glasbehälter gefüllt mit 25 ml Isopropanol
und 25ml Wasser
B)
Measured at reference setpoint temperature of +5°C