Comply with the ventilation gaps:
-
The depth of the ventilation shaft at the back of the
cabinet must be at least 38mm.
-
At least 200 cm
2
is required for the ventilation gap cross
sections in the plinth and the housing cabinet.
-
Basically, the larger the ventilation cross-section, the
more efficiently the appliance will run.
Sufficient ventilation is required for the operation of the
appliance. The ventilation grids provided ensure an effective
ventilation cross-section on the appliance of 200cm
2
. If you
replace the ventilation grids with a cover plate the ventila‐
tion cross-section must be as least as large as the ventila‐
tion grid provided by the manufacturer.
6 Custom panel weights
6.1 Weight
NOTICE
An excessively heavy custom panel can potentially cause
damage!
If the custom panel is too heavy, damage to the hinges
cannot be ruled out, which may compromise the function‐
ality of the unit.
u
Before installing the custom panel, ensure the custom
panel does not exceed the permissible weight.
Recess height (mm)* Maximum weight of custom panel
(kg)*
720 16
880 16
1020 13
1220 19
1400 21
1580 22
1780 26
Single-door fridges and freezers
Niche height
(mm)*
Maximum weight of custom panel (kg)*
Fridge compartment
door*
Freezer compart‐
ment door*
1780 18 12
Customizing combinations
7 Water connection*
If your appliance has a fixed water connection, a hose is
supplied with it.
Note
You can purchase a hose of a different length as an acces‐
sory.
Overview of dimensions
for the water connec‐
tion:
(see 7.1 Dimensions for the
water connection)
Requirements for the
water pressure:
(see 7.2 Water pressure)
Make the water connec‐
tion:
(see 15 Connecting the appli‐
ance to the water supply*)
7.1 Dimensions for the water connection
Fig.5
(a)
Maximum available
hose length*
(c) Distance of solenoid
valve to floor*
(b) Maximum available
hose length*
(M) Solenoid valve*
Fig.6
(a)
Maximum available
hose length*
(c) Distance of solenoid
valve to floor*
(b) Maximum available
hose length*
(M) Solenoid valve*
a b c
~ 1200mm ~ 1200mm ~ 55mm
7.2 Water pressure
The water connection line and solenoid valve of the appli‐
ance are suitable for a water pressure of up to 1 MPa
(10bar).
To ensure that the appliance functions correctly (flow rate,
ice cube size, noise level), maintain the following water
pressure:
Water pressure:
bar MPa
1.5 to 6.2 0.15 to 0.62
Water pressure if using the water filter:*
bar* MPa*
2.8 to 6.2 0.28 to 0.62
If the pressure is higher than 6.2bar:
u
Connect a pressure reducer.
u
Make the water connection. (see 15 Connecting the appli‐
ance to the water supply*)
8 Transporting the appliance
Observe the following when transporting the appliance:
u
Transport the appliance upright.
u
Use two people when transporting the appliance.
During the first use:
u
Transport the appliance packaged.
Custom panel weights
6 * Depending on model and options
Bekijk gratis de handleiding van Liebherr SIFNdi 5178 Peak, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Liebherr |
| Model | SIFNdi 5178 Peak |
| Categorie | Vriezer |
| Taal | Nederlands |
| Grootte | 6262 MB |
Caratteristiche Prodotto
| Apparaatplaatsing | Ingebouwd |
| Soort bediening | Touch |
| Kleur van het product | Wit |
| Deurscharnieren | Links |
| Ingebouwd display | Ja |