Handleiding
Je bekijkt pagina 10 van 20

10
MAINTENANCE
Component: Frequency: Procedure:
Fuel Tank Clean every 150-200 hours of operation or when necessary Empty and rinse with fresh fuel.
Nozzle Clean or replace once per season or when necessary Contact Lavorwash Australia Pty Ltd
Photocell Clean once per season or when necessary Contact Lavorwash Australia Pty Ltd
Fuel Filter Clean or replace twice per season or when neccesary Clean the fuel lter with clean fuel.
Ignition Device Clean or replace every 1000 hours of operation, or when necessary Contact Lavorwash Australia Pty Ltd
Blades Clean when necessary Contact Lavorwash Australia Pty Ltd
TROUBLESHOOTING / ERROR CODES
ERROR CODE CAUSE SOLUTION
E0 Operator Error:
1. The power switch is in the “ON” ( I ) position when
the heater is connected to the mains supply.
1. Disconnect the heater from the mains supply, turn the
power switch to the OFF position and reconnect to the
mains supply.
E1 Photocell Error:
1. No fuel in tank.
2. Fuel is contaminated / dirty.
3. Fuel lter is dirty / blocked.
4. Photocell is dirty or faulty.
5. Ignition error.
1. Turn the power switch “OFF” and refuel the heater.
2. Turn the power switch “OFF” and drain the fuel tank;
Clean or replace the fuel lter and rell the tank with
clean fuel.
3. Clean or replace the fuel lter
4. Contact service centre
E2 Temperature Control Sensor Error:
1. Cable fallen o or damaged.
2. Sensor faulty / damaged.
3. Ambient temperature above 60°C
1. Contact service centre.
2. Contact service centre.
3. Normal (see page 9 “Starting the Heater).
E3 Thermostat Error:
1. Heaters internal temperature is too high
2. Anti-tilt sensor activated
1. Turn the heater o and allow it to cool, then restart.
2. Set the heater on a rm surface, and restart
E4 Blower Motor Error:
1. Power cable not connected properly or damaged 2. Contact service centre
E5 Cooling Motor Error:
1. Power cable not connected properly or damaged 2. Contact service centre
Hi 1. Ambient temperature below 59°C 1 Normal (see page 9 “Starting the Heater).
LO 1. Ambient temperature below - 9°C 1 Normal (see page 9 “Starting the Heater).
CH 1. Continuous operation 55°C 1. Normal
LAVOR - IRH-70
USER MANUAL
70,000BTU - Industrial Radiant Heater
www.lavorwash.com.au
Bekijk gratis de handleiding van Lavor IRH-70, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Lavor |
Model | IRH-70 |
Categorie | Heater |
Taal | Nederlands |
Grootte | 3752 MB |