Lavex 842CD123ST12 handleiding

12 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 10 van 12
5.0 Maintenance Continued
5.2 Rinse Out Recovery Tank Continued
To rinse out recovery tank, remove the recovery tank lid and open the dump valve. Place
a bucket under the dump valve. Use a hose to rinse the dirt and debris out of the recovery
tank. Close the dump valve and spray the tank with deodorizer or disinfectant. Proceed to
waste pump cleaning and replace the recovery tank lid. Dispose of dirty water and debris.
5.3 Clean Pump Inlet Filter
CAUTION: before proceeding with this procedure, make sure both the power cords are
disconnected.
To examine the lter, open the solution tank lid on the front of the machine. The lter
is in the bottom of the solution tank.
Grasp the lter cap and unscrew the lter from the brass nipple by turning counter-
clockwise. Clean the lter by rinsing with fresh water. If necessary, use a tooth brush
to remove detergent build-up. Replace as needed.
(10) Lavex 12-Gallon, 500 PSI Carpet Extractor Lavex 12-Gallon, 500 PSI Carpet Extractor (15)
10.0 Machine Wiring Diagram
10.1 Carpet Extractor - No Heat
10.2 Carpet Extractor - Heated Unit
NOTE: a heavy build-up is a warning sign that the solution system should be ushed.

Bekijk gratis de handleiding van Lavex 842CD123ST12, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkLavex
Model842CD123ST12
CategorieNiet gecategoriseerd
TaalNederlands
Grootte3724 MB