Lavex 158LAV09WAKT handleiding

6 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 6 van 6
INSTRUCTION MANUAL6
LIQUID ADJUSTMENT
TROUBLESHOOTING
When the unit is powered on, press and hold the setting button for 3 seconds, until the LED indicator
light flashes 3 times. The LED light indicates that the unit is in standby mode.
Adjustable foaming soap settings: This unit can be set to 5 dierent levels of foam soap supply per
dispense. The default amount of liquid per dispense is .7 ml. After pressing the setting button once,
the amount will change to 1.0 ml. After additional consecutive presses, amount of liquid dispensed per
sense is as follows: 1.3 ml, 1.6 ml, and 0.4 ml.
TIP: Keep fluid container clean and free of dirt and dust to avoid blockages.
Problem Reason Potential Solution
LED INDICATOR OFF
Control System Trouble Replace the Controller
Power Supply Problem Check Circuits and Batteries
Batteries - Poor Contact or Out of Power Reinstall or Replace Batteries
Circuits - Problem or Poor Contact Check Circuits
Indicator Sight Blocked Clean the Indicator Window
LED LIGHT FLASH
Not Enough Power Replace Batteries
INDICATOR ON WITHOUT
LIQUID SUPPLY
Sensor Continue Working Remove Sensing Object
Out of Sensing Distance
Place Hand Directly Below
Sensor, Slowly Move Side to Side
and Up and Down Until Soap
Dispenses
Unit Fault Contact the Dealer
INSUFFICIENT LIQUID
SUPPLY
Short Liquid Supply Time Adjust Liquid Output
Liquid is Too Viscous Reduce Liquid Viscosity
Liquid Coagulation or Obstruction
Try Clearing Lines or Contact the
Dealer

Bekijk gratis de handleiding van Lavex 158LAV09WAKT, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkLavex
Model158LAV09WAKT
CategorieNiet gecategoriseerd
TaalNederlands
Grootte1124 MB