VS-8FDxl - Defining the VS-8FDxl Programmable 8 Port SDI Router
5
Figure 2: VS-8FDxl Programmable 8 Port SDI Router Rear Panel
#
Feature
Function
GENLOCK BNC Connector
Connect to the GENLOCK source.
LOOP BNC Connector
Connect to the GENLOCK connector of the next unit in the daisy chain.
PORTS BNC Connectors
Connect to sources and acceptors (8 in total, or 4 in total for dual mode).
RS-232 (G,Rx,Tx) Terminal
Block Connector
Connect to a PC or remote controller.
ETHERNET RJ-45
Connector
Connect to a PC via LAN and also use for firmware upgrade.
RESET Button
Press briefly to restart the system.
Press for 10 seconds to reset IP settings to factory default values.
The device powers up and loads the factory default values:
IP address: 192.168.1.39; Mask: 255.255.255.0; Gateway 192.168.1.1.
Power Socket
AC connector enabling power supply to the VS-8FDxl.
Power Switch
Illuminated switch for turning the unit ON and OFF.