40 VS-84HN - Protocol 3000
Command -
RESET
Command Type - System-mandatory
Command Name Permission Transparency
Set:
RESET
Administrator
Public
Get:
-
- -
Description Syntax
Set: Reset device
#RESET␍
Get: - -
Response
~nn@
RESET␠ OK␍␊
Notes
To avoid locking the port due to a USB bug in Windows, disconnect USB connections immediately
after running this command. If the port was locked, disconnect and reconnect the cable to reopen the
port.
Command -
SIGNAL
Command Type - System
Command Name Permission Transparency
Set: - - -
Get
SIGNAL?
End User Public
Description Syntax
Set:
-
-
Get: Get input signal lock status
#
SIGNAL?␠
inp_id
␍
Response
~ nn@
SIGNAL␠ inp_id,status ␍␊
Parameters
inp_id - input number
status - lock status according to signal validation – 0: Signal or sink is not valid, 1: Signal or sink is
valid, 2: Sink and EDID is valid
Response Triggers
After execution, a response is sent to the com port from which the Get was received
Response is sent after every change in input signal status ON to OFF, or OFF to ON
Notes