Kramer VP-8x8TP handleiding
Handleiding
Je bekijkt pagina 44 van 56

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Kramer Protocol
40
16.1 Switching Protocols
You can switch protocols either via the front panel buttons (see Section
16.1.1) or
by sending protocol commands (see Section
16.1.2).
16.1.1 Switching Protocols via the Front Panel Buttons
To switch from Protocol 3000 to Protocol 2000, press and hold
1
To switch from Protocol 2000 to Protocol 3000, press and hold the OUT 1 and
OUT 3 buttons for a few seconds.
the OUT 1 and
OUT 2 buttons for a few seconds.
16.1.2 Switching Protocols via Protocol Commands
To switch from Protocol 3000 to Protocol 2000, send the following command:
• #P2000<CR>
To switch from Protocol 2000 to Protocol 3000, send the following command:
• 0x38, 0x80, 0x83, 0x81
The Windows®-based Kramer control software
2
16.2 Kramer Protocol 3000
operates with Protocol 2000. If the
VP-8x8TP is set to Protocol 3000, it is automatically switched to Protocol 2000.
This RS-232/RS-485 communication protocol lets you control the machine from
any standard terminal software (for example, Windows
®
HyperTerminal) with
default settings of 115200 baud data rate, no parity, 8 data bits, and 1 stop bit.
16.2.1 Protocol 3000 Syntax
Host message format:
Start Address (optional) Body Delimiter
#
Destination_id@ message
CR
Simple command (commands string with only one command without addressing):
start
body
delimiter
# Command SP Parameter_1,Parameter_2,…
CR
Commands string (formal syntax with commands concatenation and addressing):
# Address@ Command_1 Parameter1_1,Parameter1_2,… |Command_2
Parameter2_1,Parameter2_2,… |Command_3 Parameter3_1,Parameter3_2,…
|…CR
1 Not as part of a switching operation
2 Download the latest software from our Web site at
http://www.kramerelectronics.com