Kramer Electronics Ltd.
ASPEN-32UFX, ASPEN-1616UX, VS-8UFX – Protocol 3000
45
LOGIN
Functions
Permission
Transparency
Set:
LOGIN
Not Secure
Public
Get:
LOGIN?
Not Secure
Public
Description
Syntax
Set:
Set protocol permission
#LOGIN␠login_level,password␍
Get:
Get current protocol permission level
#LOGIN?␍
Response
Set: ~nn @LOGIN␠login_level,password␠OK␍␊
or
~nn@LOGIN␠ERR␠004␍␊ (if bad password entered)
Get: ~nn@LOGIN␠login_level␍␊
Parameters
login_level – level of permissions required: User, Admin
password – predefined password (by PASS command). Default password is an empty string
Response Triggers
Notes
When the permission system is enabled, LOGIN enables running commands with the User or
Administrator permission level.
When set, login must be performed upon each connection.
The permission system works only if security is enabled with the SECUR command. It is not mandatory to
enable the permission system in order to use the device.
Example
Set the protocol permission level to Admin (when the password defined in the PASS command is 33333):
#LOGIN Admin,33333<CR>
LOGOUT
Functions
Permission
Transparency
Set:
LOGOUT
Not Secure
Public
Get:
-
-
-
Description
Syntax
Set:
Cancel current permission level
#LOGOUT␍
Get:
-
-
Response
~nn@LOGOUT␠OK␍␊
Parameters
Response Triggers
Notes
Logs out from User or Administrator permission levels
Example
#LOGOUT<CR>
Bekijk gratis de handleiding van Kramer ASPEN-1616UX, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Kramer |
| Model | ASPEN-1616UX |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 9931 MB |
Caratteristiche Prodotto
| Kleur van het product | Zwart |
| Gewicht | 1000 g |
| Breedte | 436.4 mm |
| Diepte | 100 mm |
| Hoogte | 43.6 mm |