Kramer Electronics Ltd.
ASPEN-32UFX, ASPEN-1616UX, VS-8UFX Protocol 3000
40
NAME-RST
Command Name
Permission
Transparency
Set:
NAME-RST
Administrator
Public
Get:
-
-
-
Description
Syntax
Set:
Reset unit name to factory default
#NAME-RST
Get:
-
-
Response
~nn@NAME-RSTOK␍␊
Parameters
Response Triggers
Notes
Factory default unit name is “model_name-” + 5 last digits of unit serial number.
Example
Reset unit name to factory default:
#NAME-RST<CR>
PORT-DIRECTION
Command Name
Permission
Transparency
Set:
PORT-DIRECTION
End User
Public
Get:
PORT-DIRECTION?
End User
Public
Description
Syntax
Set:
Set port direction for an
interchangeable video port
#PORT-DIRECTIONport_index,direction␍␊
Get:
Get port direction for an
interchangeable video port
#PORTDIRECTION?port_index ␍␊
Response
Set / Get: ~nn@PORT-DIRECTIONport_index,direction␍␊
Parameters
port_index port number from the front panel (1-n)
direction IN (input), OUT (output)
Response Triggers
Notes
This command applies only to ASPEN-32UFX and VS-8UFX.
Example
Set port #5 to be an output:
#PORT-DIRECTION 5,OUT<CR>