Kramer ASPEN-1616UX handleiding
Handleiding
Je bekijkt pagina 38 van 60

Kramer Electronics Ltd.
ASPEN-32UFX, ASPEN-1616UX, VS-8UFX – Protocol 3000
36
BUILD-DATE
Functions
Permission
Transparency
Set:
-
-
-
Get:
BUILD-DATE?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get device build date
#BUILD-DATE?␍
Response
~nn@BUILD-DATE␠date␠time␍␊
Parameters
date – Format: YYYY/MM/DD where YYYY = Year, MM = Month, DD = Day
time – Format: hh:mm:ss where hh = hours, mm = minutes, ss = seconds
Response Triggers
Notes
Example
#BUILD-DATE?<CR>
FACTORY
Functions
Permission
Transparency
Set:
FACTORY
End User
Public
Get:
-
-
-
Description
Syntax
Set:
Reset device to factory default configuration
#FACTORY␍
Get:
-
-
Response
~nn@FACTORY␠OK␍␊
Parameters
Response Triggers
Notes
This command deletes all user data from the device. The deletion can take some time.
You must power cycle the device for the changes to take effect.
Example
#FACTORY<CR>