Handleiding
Je bekijkt pagina 110 van 137

110
© 2021 KOSTAL Solar Electric GmbH
Maintenance
7.5 Replacing PV fuse
The PV fuse in the PIKO CI 50/60 can be replaced. If an
event prompting this is displayed, the inverter must be
disconnected from the grid on the DC and AC sides.
1. Inverter on DC and AC sides voltage-free
Ch. 4.3.
2. Wait at least 10 minutes after the inverter has been
switched o.
3. Open the lower section of the inverter.
PIKO CI 50/60
Fig. 33: PIKO CI 50/60 inverter (PV fuses)
1
PV fuses
4. Use a multimeter to identify and replace defective
fuses.
5. Install cover and screw it tight (1.5Nm).
6. Switch on the inverter again.
H
The PV fuses have been replaced.
DANGER
RISK OF DEATH DUE TO ELECTRI-
CAL SHOCK AND DISCHARGE!
Life-threatening voltages are pres-
ent in the inverter. Only a qualified
electrician may open and perform
work on the device.
Disconnect all poles of the device
(AC and DC side) before starting
work.
Wait at least 10 minutes after dis-
connecting the unit until the inter-
nal capacitors have discharged.