Pipe Length and Additional Refrigerant
Inverter models
capacity (Btu/h)
9K-12K 18K-24K 30K-36K
Length of pipe with
standard charge
5m/
16ft
5m/
16ft
5m/
16ft
5m/
16ft
5m/
16ft
5m/
16ft
Length of pipe with
standard charge (Like:
North American, etc.)
7.5m/
24ft
7.5m/
24ft
7.5m/
24ft
7.5m/
24ft
7.5m/
24ft
7.5m/
24ft
Maximum distance
between indoor and
outdoor unit
15m/
49ft
15m/
49ft
20m/
65ft
20m/
65ft
30m/
98ft
30m/
98ft
Additional refrigerant
charge
20g/
m
15g/
m
30g/
m
25g/
m
30g/
m
25g/
m
Max. diff. in level
between indoor and
outdoor unit
10m/
32ft
10m/
32ft
15m/
48ft
15m/
48ft
20m/
65ft
20m/
65ft
Type of refrigerant
R22/
R410
A
R32
R22/
R410
A
R32
R22/
R410
A
R32
ON-OFF models’ capacity
(Btu/h)
9K-12K 18K-36K
Length of pipe with standard
charge
5m/16ft 5m/16ft 5m/16ft 5m/16ft
Maximum distance between
indoor and outdoor unit
15m/49ft 15m/49ft 15m/49ft 15m/49ft
Additional refrigerant charge 20g/m 15g/m 30g/m 25g/m
Max. diff. in level between
indoor and outdoor unit
5m/16ft 5m/16ft 5m/16ft 5m/16ft
Type of refrigerant R22/R410A R32 R22/R410A R32