Kimo C 310 handleiding
Handleiding
Je bekijkt pagina 14 van 34

3.2.11 Access to the transmitter information
This part allows to access to the information about the transmitter, the boards and the probes.
➢ Press OK on “Information” line.
A 1
st
 screen is displayed with information about the transmitter (name, serial number, calibration date).
➢ Press Right arrow.
The screen displays information about the outputs.
➢ Press Right arrow.
The screen displays information about the connected boards.
➢ Press Right arrow.
The screen displays information about the connected probes.
➢ Press Esc key to quit the information screen.
3.3.  Configure the measurement channels
This part allows to activate and assign a measurement channel to a probe or a board.
By default, channels are activated according to the supplied conguration of the transmitter. This conguration is indicated 
on the label located on the side of the transmitter.
To activate a channel, at least one probe or one board must be connected to the transmitter.
➢ Press OK.
➢ Enter the security code then press OK.
➢ Go to the “Channel” line then press OK.
The transmitter displays the 4 available channels.
➢ Go to the line of the channel to activate then press OK.
The transmitter displays “Probe – Unit OFF”.
➢ Press OK.
➢ Select with Right and Left arrows “Probe 1”, “Probe 2” or “Board” according to the required attribution for 
the channel.
The available units of the selected probe or board appear.
➢ Select the unit with Up and Down arrows then press OK.
The transmitter displays the feature of the channel.
•
the type of probe (probe1, probe 2 or board) and its unit
•
the coefcient
•
the offset
➢ Modify if necessary the coefcient and offset.
3.4.  Configure the analogue outputs
One channel must be congured at least (see chapter 3.3).
If no channel has been congured, the transmitter will indicate that the outputs conguration is 
impossible.
➢ Press OK.
➢ Enter the security code.
3.4.1 Select the type of output
➢ Go to “Analogue outputs” line then press OK.
The transmitter displays the available analogue outputs: by default, outputs 1 and 2 are available. Outputs 3 and 4 
are available as option.
➢ Go to the output to congure with Up and Down arrows then press OK.
14
Congure the transmitter
Bekijk gratis de handleiding van Kimo C 310, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.