ASSEMBLY INSTRUCTIONS
5
A
B
DD
4
CC
EE
Hardware Used
x 3Wire Connector
AA
3. Wire connection guide:
Ground wire:
• For installation in the United States: Wrap
ground wire from outlet box around ground
screw preassembled on mounting bracket
(B) no less than 2 in. from wire end. Tighten
ground screw. If fixture is supplied with a
ground wire, connect to outlet ground wire
with a wire connector (AA).
• For installation in Canada: If fixture is
supplied with ground wire, wrap ground wire
around ground screw on mounting bracket
(B). Tighten ground screw. Connect fixture
ground wire to outlet ground wire with the
wire connector (AA).
Supply wires:
• Connect the Neutral (White) supply wire from
the outlet box to the Neutral fixture wire
(White or Parallel Cord “D” shaped and
ribbed).
• Connect the Hot (Black) supply wire from the
outlet box to the Hot fixture wire (Black or
Parallel Cord round and smooth).
3
BARE COPPER,
OR GREEN
GROUND
SUPPLY WIRE
BARE COPPER,
OR GREEN
GROUND
FIXTURE
WIRE
BLACK FIXTURE
WIRE
WHITE FIXTURE
WIRE
BLACK SUPPLY
WIRE
BLACK SUPPLY
WIRE
PARALLEL
FIXTURE CORD
(ROUND AND
SMOOTH)
PARALLEL FIXTURE
CORD (“D” SHAPED
AND RIDGED)
OR
WHITE SUPPLY
WIRE
WHITE SUPPLY
WIRE
AA
x 2
CC
Threaded Knob
Hardware Used
x 2
EE
Lock Washer
4. Pass canopy (A) over the long
machine screws (DD) protruding from the
mounting bracket (B) and secure in place
with lock washers (EE) and threaded
knobs (CC).