Air Conditioner
Features
Page 25
NOTE:
If the unit breaks off unexpectedly due to the
power cut, it will restart with the previous
function setting automatically when the
power resumes.
TIMER: AUTO START/STOP FEATURE:
ADDITIONAL THINGS YOU SHOULD KNOW
DISPLAYS:
Now that you have mastered the operating
procedure, here are more features in your
control that you should become familiar with.
• The Cool circuit has an automatic 3 minutes
time delayed start if the unit is turned off and
on quickly.
This prevents overheating of the compressor
and possible circuit breaker tripping.The fan
will continue to run during this time.
• The control is capable of displaying tempera-
ture in degrees Fahrenheit or degrees Celsius.
To convert from one to the other, press and
hold the Up and Down buttons at the same
time for 3 seconds.
• Turning the unit ON or OFF at any time or a
djusting the timer setting to 0.0 will cancel the
Auto Start/Stop timed program.
Shows the set temperature in °C" or °F" and
the Auto-timer settings.While on Fan only mode,
it shows the room temperature. If the room
temperature is too high or low, it will display
" HI" or " LO".
Error codes:
AS - Room temperature sensor error
ES -Evaporator temperature sensor error
NOTE:
"" is displayed as shown in the obove
picture.
CS -Condenser temperature sensor error
OS -Outside temperature sensor error
E7 -Unit malfunction
NOTE:
When error occurs,unplug the unit and
plug it back in.If error repeats, call for service.
To operate on Auto feature:
When you set the air conditioner in AUTO mode,
it will automatically select cooling, or fan only
operation depending on what temperature you
have selected and the room temperature.
The air conditioner will control room temperature
automatically round the temperature point set
by you.
In this mode, the fan speed cannot be adjusted,
it starts automatically at a speed according to the
room temperature.
To operate on Fan Only:
Use this function only when cooling is not
desired,such as for room air circulation or to
exhaust stale air (on some models). (Remember
to open the vent during this function, but keep
it closed during cooling for maximum cooling
efficiency.) You can choose any fan speed you
prefer.
During this function, the display will show the
actual room temperature, not the set temperature
as in the cooling mode.
In Fan only mode ,the temperature is not adjusted.
To operate on Dry mode:
In this mode, the air conditioner will generally
operate in the form of a dehumidifier. Since the
conditioned space is a closed or sealed area, some
degree of cooling will continue. On Dry mode,the
fan speed is controlled at Low automatically.
Displays
is
off,there
is
no
display.)
temperature
when
the
unit
is
on.(when
the
unit
the
previous
temperature
setting
or
room
the
system
will
automatically
revert
back
to
display
The
selected
time
will
register
in
5
seconds,
and
until
start.
The control
will
count
down
the
time
remaining
hours,then
at
1
hour
increments
up
to
24
hours.
the Auto
time
by
0.5
hour
increments,
up
to
10
Press
or
hold
the
UP
or
DOWN
button
to
change
the
timer
settings.
units,
keep
pressing
the
Timer
button
will
cancel
Start
or
Auto
Stop
program
is
initiated. For
some
OFF
indicator
light
illuminates.
It
indicates
the
Auto
Press
Timer
button,
the
TIMER
ON
or
TIMER

Bekijk gratis de handleiding van Keystone KSTAW08CE, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.