Door call via the storey call button
3 Hold down the storey call button
connected to the bus indoor device
for 4 seconds. The bus indoor device
is now in the programming mode.
During this period, no ringing is
admissible within the system.
Programming is only possible when
the storey call button (ERT) is con-
nected to the bus indoor device.
If there is no access available to an
apartment, programming can still be
carried out in this way.
2 At the door station, hold down
the light/programming button for
4seconds. A protracted acknowl-
edgement tone is then audible
which is repeated every 5seconds
as long as the programming mode
remains active.
1 Switch on the programming mode.
At the BNG/BVNG650-…, press the
programming mode button briey.
The LED1 ashes in a 2-second
rhythm to indicate that the program-
ming mode is active.
4 At the door station, hold down the
required call button for 4seconds
until a protracted tone sounds at the
door loudspeaker. The call button
is now assigned to the bus indoor
devices, no speech connection now
exists.
5 The call button is now rmly
assigned to the bus indoor devices.
Program additional users using the
same procedure or quit the pro-
gramming mode.
101