6 Installation
General information
Consumers Voltage Current
Door release 12 VAC appr. 600 mA
Vario bus call button module
(BTM650-01 to -04)
12 VAC max. 20 mA
Steel button illumination 12 VAC
10–30 VDC
max. 3 mA
Classic button illumination CL…-01 12 VAC
10–30 VDC
max. 25 mA
max. 30 mA
Classic button illumination CL…-02 12 VAC
10–30 VDC
max. 5 mA
Models Terminal
assignment
Voltage Current
BNG650-… Ta, Tb 27.5VDC 500mA
b, c 12VAC 1000mA
NG602-… +, - 23.3VDC 300mA
b, c 12VAC 1600mA
TR603-… b, c 12VAC 1300mA
TR602-… b, c 12VAC 2500mA
VNG602-… +M, -M 30VAC 1100mA
Terminals
AIB150-…
BTS/BTC/BFC850-…
Ta, Tb In-Home bus: Audio
ERT Storey call button
Optionally
Terminals
ZAR/ZARF850-…
S1/S1 Potential-free contact
15VAC, 30VDC, 1A
Note
As in the as-delivered/de-energized
status, the contact position of the
bistable relay (contact S1/S1) cannot
be dened, the bus supply to the
device must be connected before-
hand to ensure that the bistable
relay functions correctly.