Light control priority system
Priority
1. (Highest)
Control hierarchy
Operating mode switch
2.
Restraint
No lower-priority commands are executed
3.
Local operation
With the operating button, for example. Lower-priority com-
mands received following local operation are then executed.
4. Local automatic system
5. Commands received wirelessly
6. (Lowest) Scene
electronic operating device, con-
trol units for DALI or 1 10 V control.
Universal dimmers
In addition to the classic lamp tech-
nology, the universal dimmer is also
suitable for dimmable HV LEDs or
LV LEDs with transformers.
Universal dimmers detect the char-
acteristics of the connected load
and independently select the appro-
priate dimming principle leading
edge phase control or trailing edge
phase control.
On the device, the dimming princi-
ple can be specified using the oper-
ating mode switch.
1 10 V or DALI operating devices
Lamp operating devices with a
1 10 V or DALI interface control the
lamp brightness directly in the elec-
tronic ballast (EB). Brightness con-
trol units are used for this purpose.
3. BUTTONS FOR
SWITCHING/DIMMING
INSERTS
Adding eNet operating top units to
the flush-mounted inserts turns
the inserts into eNet actuators.
This button contains a transmitter/
receiver module, and transmits
the commands received from the
eNet transmitters to the insert and
transmits the actuator status back
to the transmitter. This combination
can be operated on the button it-
self, using connected push-buttons
or auxiliary unit inserts, or using
transmitters or the eNet server.
4. LIGHT CONTROL
HIERARCHIES
A higher-priority command re-
mains active until it is cancelled by
the same or a higher hierarchy lev-
el. Lower-priority commands are
blocked during this time.
Commands that were not executed
previously are not subsequently ex-
ecuted once a higher-level control
is cancelled. Generally speaking,
the device behaviour at the end of
a higher-level command is adjust-
able depending on the actuator
type.
Device setup:
1. Flush-mounted insert
2. Cover frame
3. eNet operating top unit
4. Status LED
6968 eNet _ Switching, pressing and dimming