JANDY JSWC53 handleiding

72 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 31 van 72
Page 31
Jandy
®
Commercial Salt Chlorinator | Installation & Operation Manual ENGLISH
6.4 Winterizing
Very little chlorine is needed in cold water. Below
51°F (11°C), operating the chlorinator in cold water
might result in over-chlorinated pool water.
If preventative measures are not taken, freezing
water may cause severe damage to the cell and
flow/ temp/salinity sensor. Prevent freeze damage
to the cell and flow/temp/salinity sensor by running
pump continuously or winterize pool by draining
water from pump, filter, and all intake and return
lines. Remove the cell, clean and store it.
When a FREEZE CONTROLLER is used on pump
equipment and the chlorinator is run through the
winter, turn the CHLORINE PRODUCTION down to
10 - 20%. Otherwise, chlorine production will exceed
the recommended level of 1 - 3 ppm.
NOTE: A chlorine level above 3 ppm may cause corrosion
of pool metals and possibly cause damage to
associated pool equipment.

Bekijk gratis de handleiding van JANDY JSWC53, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkJANDY
ModelJSWC53
CategorieNiet gecategoriseerd
TaalNederlands
Grootte16458 MB