Step 2. Connect Electrical Wiring
IMPORTANT
Refer to the IMPORTANT SAFETY INSTRUCTIONS at the beginning of this
manual for important electrical hazard information.
1. Turn off all electrical power to the system.
2. Connect the ozone generator to the “load side” of the lter pump
relay.
NOTE: The ozone generator must not be powered on when the pump is turned off.
3. Install conduit tting through one of the knockouts. There are
three knockouts on the generator for a 1/2 in. conduit tting (one
on the back, two on sides).
4. Locate the Terminal Block inside enclosure. (Refer to wiring
diagram on the label inside the enclosure door, see Figure 2.)
Wiring
Information
Figure 2. Wiring Information Label
5. For 120V, connect Line to L1, Neutral to L2, and Ground to the
terminal block, as indicated on the label inside the enclosure
door (see Figure 2).
6. Using a 6 AWG (13.3 mm
2
) conductor, connect the grounding
lug on the bottom of the ozone generator to an appropriate
earth contact.