Jandy
®
Pro Series Ozone Generator
2.3 Power Requirements
MODEL
NUMBER
RATED VOLTAGE
RANGE
MAX
CURRENT
POWER
FREQUENCY
CD40 120-240 VAC 0.17A 50-60 Hz
CD70 120-240 VAC 0.29A 50-60 Hz
CD100 120-240 VAC 0.40A 50-60 Hz
2.4 Installation Location Requirements
The generator must be mounted (as follows):
In a clean, protected area, either indoors or outdoors
(preferably out of direct sunlight) an ideal ambient
temperature between
32°F - 120°F (0°C - 50°C)
Out of reach of sprinklers or drainage spouts.
With sufficient access for maintenance, tubing, and electrical
wires.
At least one foot above the maximum water level.
So that the bottom of the enclosure is at least three (3) feet
above ground, and such that the center of the enclosure is
no more than six (6) feet above ground.
NOTE: The maximum height requirement is to allow an
average height person to service comfortably.
Section 3. Installation
Step 1. Mount the Generator
NOTE: Remove and discard all foam packaging from inside the
enclosure before mounting the unit.
1. Unscrew two (2) screws to open the enclosure door.
2. Locate the three mounting holes in the back of the enclosure
(see Figure 1).