JANDY CD100 handleiding

24 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 3 van 24
Page 3
Jandy
®
Pro Series Ozone Generator
Section 1. Important Safety Instructions
READ AND FOLLOW ALL INSTRUCTIONS
All electrical work must be performed by a licensed electrician and
conform to all national, state, and local codes. When installing and
using this electrical equipment, basic safety precautions should
always be followed, including the following:
DANGER
ELECTRIC SHOCK HAZARD Be sure to turn power OFF and disconnect from
power source before any routine maintenance is performed. Failure to install in
accordance with installation instructions could result in serious injury or death.
WARNING
ELECTRIC SHOCK HAZARD - Install at least 5 feet (1.5 meters) from wall
of pool using nonmetallic tubing. Install ozone generator no less than one (1)
foot above maximum water level to prevent water from contacting electrical
equipment. Install in accordance with the installation instructions.
- A pressure wire connector is provided on the outside of the unit, marked with
“Bonding Lugs” to permit connection to a minimum No. 6 AWG (13.3 mm
2
)
solid bonding conductor between this point and any metal equipment, metal
enclosures of electrical equipment, metal water pipes, or conduit within ve (5)
feet (1.5m) of the unit or as needed to comply with local requirements.
- The Jandy Pro Series Ozone generator must be installed in an outdoor
location, or indoors in a forced air ventilated room, and installed so that the
orientation is exactly as shown in Figure 1. Install to provide water drainage of
generator to protect electrical components.
- Mount the Jandy Pro Series Ozone generator so that it is inaccessible to
anyone in the pool. Never attempt any servicing while unit is wet.
- Plastic ozone supply tubing is supplied with the Jandy Pro Series Ozone
generator. Never replace this tubing with metal tubing.
- A green-colored terminal or a terminal marked G, GR, Ground, Grounding, or
the symbol is located inside the supply terminal box or compartment. To re-
duce the risk of electric shock, this terminal must be connected to the ground by
the means provided in the electric supply service panel with a continuous copper
wire equivalent in size to the circuit conductors supplying this equipment.
WARNING
ELECTRIC SHOCK HAZARD To reduce the risk of electrical shock, this device
must be mounted such that it is inaccessible to a person in the pool.
WARNING
ELECTRIC SHOCK HAZARD Follow all applicable electrical codes.

Bekijk gratis de handleiding van JANDY CD100, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkJANDY
ModelCD100
CategorieNiet gecategoriseerd
TaalNederlands
Grootte2422 MB