Jackson FlightStar handleiding
Handleiding
Je bekijkt pagina 29 van 90

07610-004-81-74-A
21
1. Check the amperage draw for each connection point; this should be done only
by qualied electricians since this involves working with energized components.
Compare the amperage draw for each section to what is listed on the data plate
and/or to maintenance records. Any signicant change in amperage draw could
be indicative of a major component (motor or heater) failing and should be
investigated further to determine the exact cause of the change.
2. Verify the machine is maintaining proper temperatures as indicated on the machine
data plate. Start the machine and allow it to run in low speed with the exhaust
fan and blower turned on. Do not load any ware onto the machine. Let run for
approximately 15 minutes before starting to observe temperatures. Compare the
temperatures to what is listed on the machine data plate. If there is a discrepancy,
investigate and correct.
3. Verify the machine is still level. A level machine is required for peak eciency
as water levels can be aected due to any incline. This should be done with the
machine o, cooled down, and drained.
4. Delime the electric booster heater. In order to maintain the electric booster heater
at its optimum performance level, lime and corrosion deposits must be removed
on a frequent basis. To delime, refer to the instruction manual that came with the
electric booster heater. A deliming solution should be available from your chemical
supplier. Read and follow all instructions on the label of the deliming solution.
1. The manufacturer recommends that at least once a year a general, overall
inspection of the machine is performed. With the machine drained and power
secured at the service breaker, service personnel should look for any items
needing addressed that might not be specically pointed out in the preventative
maintenance procedures. Examples of things to look for include:
• Loose screws.
• Frayed wires.
• Broken lights or switches.
• Torn curtains.
Experience will dictate to service personnel specic items that should be examined
and the manufacturer encourages scheduling inspections as often as needed to
ensure any problems do not become catastrophic.
QUARTERLY
MAINTENANCE
ANNUAL
MAINTENANCE
PREVENTATIVE MAINTENANCE
MAINTENANCE
i
NOTICE
Bekijk gratis de handleiding van Jackson FlightStar, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Jackson |
| Model | FlightStar |
| Categorie | Vaatwasser |
| Taal | Nederlands |
| Grootte | 12592 MB |