To maintain the machine at its optimum performance level, lime and corrosion
deposits must be removed. Water conditions will determine the frequency for
deliming. A deliming solution is available from your chemical supplier. Read and
follow all instructions on the label.
To delime the machine:
1. Disconnect or turn o all chemical feeder equipment.
2. Remove rinse arms and place in sink with deliming solution.
3. Verify standpipe is in position, turn the machine on, and allow the
machine to complete a ll cycle.
4. Open door and verify water level is above standpipe. Add deliming
solution per the solution manufacturer’s recommendation (water capacity
of tank can be veried in Specications section of this manual).
5. Close door and push delime button on display.
6. Delime cycle runs for eight minutes.
7. Once delime cycle stops, pump will automatically stop.
8. Open door and lift standpipe.
9. Wait ve minutes, then inspect inside of the machine. If the machine is
not delimed/free of scale, run again.
10. When clean, drain and rell the machine.
11. Run a cycle to remove residual deliming solution.
12. Reinstall rinse arms.
13. Drain and rell the machine.
DELIMING
OPERATING INSTRUCTIONS
OPERATION