19
07610-004-99-71-B
TROUBLESHOOTING
SETPOINTS
ADJUSTING
WASH TEMP
SETPOINT
To access setpoints, the machine should be on and not in cycle.
1. Push and hold cycle button for a minimum of six seconds. Wash temperature
shows on left display and will ash on and o.
2. Once button is released, press prime button (upper rocker to increase and lower
rocker to decrease). This changes wash temperature one degree at a time to a
maximum of 170 °F or a minimum of 150 °F.
3. Once desired temperature is selected, press and hold cycle button for a
minimum of three seconds and no more than six seconds (after three seconds
wash temperature will stop ashing). Release cycle button to accept and move
to next setting (rinse temperature).
1. Once setting changes to rinse temperature, rinse temperature shows on left
display and will ash on and o.
2. Press prime button (upper rocker to increase and lower rocker to decrease).
This changes rinse temperature one degree at a time to a maximum of 192 °F
or a minimum of 180 °F.
155
°
F
160
°
F
160
°
F
ADJUSTING
RINSE TEMP
SETPOINT
180
°
F
190
°
F
If there is no activity
(button presses) for 30
seconds, display will exit
setpoints mode without
saving changes.
If there is no activity
(button presses) for 30
seconds, display will exit
setpoints mode without
saving changes.