OPERATION INSTRUCTIONS (continued)
LED CODE CHART
Chlorine Electrode Self-Clean cycle:
The default self-clean cycle time is 04 hours. To adjust the self-clean cycle time:
•
Press ( ) button and then press ( ) button, the display is flashing.
Depending on your pool water calcium hardness level, press ( ) button
again to select the self-clean cycle time per below table. Total of 4 settings:
02H, 04H, 06H and 10H. If you selected 02H, it will be increased to 04H
automatically after the system has accumulated 300 hours of self-clean cycle
time.
NOTE:
The life of the chlorine electrode varies depending on water conditions, pool usage and
operating time of the system. Select 10 hours cycle time to extend the life of the chlorine electrode if the
calcium hardness level is up to 150 ppm. Manual routine cleaning and maintenance will further lengthen
the life of the chlorine electrode.
•
Press ( ) button to lock the keypad and the display will return to the normal operating time. The
system will reverse the polarity of the chlorine electrode
(3)
every time according to the selected hours.
NOTE:
If you forget to lock the keypad, the system will automatically lock it after 10 seconds.
Water Calcium Hardness Self-clean cycle time
0 - 150 ppm Reverse polarity every 10 hours
150 - 250 ppm Reverse polarity every 6 hours
250 - 350 ppm Reverse polarity every 4 hours
350 - 400 ppm Reverse polarity every 2 hours
LED Reading Definitions
00H Stand-By Mode (Start-up)
01H Minimum Operating Hour (1 hour remaining)
02H - 11H Operating Hours (2 - 11 hours remaining)
12H Maximum Operating Hours (12 hours remaining)
E01 Alarm Code (Scale, dirt on chlorine electrode, loose chlorine electrode cord)
E02 Alarm Code (Chlorine electrode failure)
E03 Alarm Code (Water temperature < 10 °C / 50 °F)
E04 Alarm Code (Water temperature > 40 °C / 104 °F)
E90 Alarm Code (Low Pump Flow/No Pump Flow)
E91 Alarm Code (Low Salt Level)
E92 Alarm Code (High Salt Level)
93 Stand-By Mode (Operating Process finished)
E97 Internal PCB failure
E99 2-in-1 (salt / temperature) sensor faulty, malfunction
“BLANK” No Power or “Power Saving Mode” waiting to start next Saltwater System cycle.
NOTE:
See “
Troubleshooting Guide
” section for details.