Intermatic PE953 handleiding
Handleiding
Je bekijkt pagina 45 van 51

Seven: Troubleshooting 45
Providing a brighter solution.™
Problem What to do Reference/Procedure
The heater turns
OFF but gets very
hot after the pump
turns OFF.
Verify that the
heater has a proper
“TimeInterval”
programmed for cool
down.
TheFiremanSwitchTimeIntervalisdened
as the additional time the pump will run after
the heater circuit (circuit 5) is turned off to
make sure the heater is cooled down before
it shuts off.
Refer to “Conguring the Fireman’s Switch Time
Interval” starting on page 14 in this manual.
Problem What to do Reference/Procedure
The System will
not respond to
commands from
the Hand-Held
Controller
Verify that the
Antenna section is
properly installed on
the top portion
IftheAntennasectionhasbeenremovedfor
installation of any type of wiring connection,
check the following.
1. Wires are properly wired and routed through
the knockouts in the antenna cover.
2. Verify that all of the local antenna connector
pins on the PE653 art straight and properly
inserting into the plug on the Antenna
section.
3. Verify that the Antenna Section is completely
seated on the PE653 housing.
4. Refer to the “Testing Z-Wave Reception”
section starting on page 18.
Problem What to do Reference/Procedure
Water or moisture
is visible inside the
screen of the Hand-
Held Controller.
Dry out the Hand-
Held Controller.
1. Remove the battery cover on the rear of the
PE953 Hand Held Controller. Refer to page
24 for instructions.
2. Gently drain any water remaining in the
Hand-Held Controller.
3. Place the Hand-Held Controller in a well
ventilated area to dry.
CAUTION: Do not place in direct sunlight.
4. Insertnewbatterieswhenalltracesof
moisture are gone from the screen.
NOTE: Be sure to re-install the gasket correctly
to create a water-tight seal. Refer to page 24
for instructions.
5. Ifrequired,followprogramminginstructions
starting on page 9.
Problem If it doesn’t work Reference/Procedure
The Hand-Held
Controller appears
to be “LOCKED
UP”.
Power down the
Controller to reset.
1. Remove the batteries from the PE953 Hand-
Held Controller.
2. Allow 15 seconds before replacing the
batteries. Refer to page 24 for instructions.
NOTE: Be sure to re-install the gasket correctly
to create a water-tight seal. Refer to page 24
in this manual for instructions.
3. Ifrequired,followprogramminginstructions
starting on page 9.