16 Multi-Wave PE953 Installation Guide
Copyright © 2011 Intermatic, Inc.
10.Press the <2> function button to select the ON time
for the second event, and repeat Steps 7 through 9
to set the times. The event will now activate (ON)
or deactivate (OFF) according to the times you have
set.
11.Press the <P/S> function button to advance to the
next circuit.
NOTE: To delete and reset all the events for one circuit you have scheduled
or the current circuit (or VSP Speed) being congured, press the <4>
function button. The screen displays reset instructions. You have two options:
• Press the <5> function button to continue with the reset.
• Press the <ENTER> button to cancel the reset.
Conguring the Freeze Temperature (optional)
IfthesystemhasanoptionalIntermaticFreezeSensor(178PA28A),youcan
setthetemperaturewhereanyspeciedCircuitwillturnONtoprotectthe
pool.
1. Ifnecessary,pressandreleaseanybuttononthe
Hand-Held Controller to wake it from sleep. If the
screen is not displaying LEARN MODE, press and hold
the <P/S> and <ENTER> buttons at the same time
aerdto put the device into programming mode. You
are in programming mode when the LEARN MODE
screen is displayed, as shown at the right.
2. Press the DOWN arrow as necessary to view the
FREEZEOPTIONscreen,asshown.
NOTE: If a variable speed pump is installed, this
screen will also display the VSP SPEED, as shown
in this example.
3. Press and release the <1> function button to select
TEMP. The screen refreshes, as shown.
4. Press the UP or DOWN arrow button to change
fromDISABLEDtothetemperatureyouwant(the
valid selectable range is from 34°F to 44°F), then
press the <ENTER> button. The screen displays
the word SUCCESSFUL, then returns to FREEZE
OPTIONscreen.
5. Next, press and release the <2> function button to
select the circuit(s) you want to turn on when the
freeze temperature is reached. The screen refreshes,
as shown.
6. Press the appropriate button(s) for the circuit on the Hand-Held
Controller, then press the <ENTER> button.
- Ifyouhaveasingle-speedpump,pressandreleasethe <1> function button.
- Ifyouhaveatwo-speedpump,pressandreleasethe <1> function
button to circulate water and prevent freezing with the high speed, or
the <2> function button to circulate with the low-speed.
- Ifyouhaveavariablespeedpump,returntoStep3andselectthe <3>
function button to pick the VSP speed (if any) you want to activate.
NOTE: Other options available will depend on how the system is
congured (e.g., reman enabled or not, booster enabled or not, etc).
7. Press the <ENTER> button again to return to the Main screen.
Conguring for a Variable Speed Pump (optional)
Ifavariable-speedpumphasbeeninstalledforthe
lterandcleanerpumpfunctions,theHand-Held
Controller can be toggled between the PE653 screen
andthisvariablespeedcontrolscreen(VARSPDINT)
by pressing and releasing the <ENTER> button.
This screen controls the variable speed pump,
andcanbeconguredtodisplaythefunctionalitiesyouhaveselectedfor
various pump speeds (for example, slowest speed for the cleaner, next faster
speed for a booster pump, etc.).
Buttons <1> through <4> on the Hand-Held Controller choose between the
4 speeds, allowing you to toggle them from ON to OFF and vice-versa.
Youcanchangethefourvariablespeedpumpspeedsettingsfromthe
factory default values by following these steps on the Hand-Held Controller.
Oncecongured,Buttons<1> through <4> will switch between the
variable speeds according to your settings.
1. Ifnecessary,pressandreleaseanybuttonontheHand-HeldControllerto
wake it from sleep.
2. Press the <ENTER> button to display the variable
speedscreenVARSPDINTasshown.
3. Press and hold the <P/S>buttonrst,thenpress
and hold the <ENTER> button within 2 seconds.
The LEARN MODE screen is displayed.
NOTE: If you don’t press and hold the <ENTER>
button within 2 seconds then the displayed
time may highlight, and the LEARN MODE
screen will NOT display. Release both the
<P/S> and the <ENTER> buttons, then press
<ENTER> to un-highlight the displayed time.
Repeat this procedure from the beginning until the LEARN MODE
screen is displayed.
4. Press the DOWN arrow button until you see the
VSP SPEEDS screen, as shown.
NOTE: The MAX SPEED setting is the highest
speed the pump can safely operate without
damaging the plumbing system.
5. Press and release the <1> function button to set
the speed for that button. The screen displays that speed.
6. Press the UP or DOWN arrow button to raise or
lower the speed setting.
7. Repeat Steps 5 and 6 to set speeds for button <2>
through <5>.
8. Press the <ENTER> button again to return to the
VARSPDINTscreen.