69
Parameter Category Setting
Default
value Description/Setting range
P128P128
Bivalent
Activation/deactivation of the heat
pump blockage program; see §11.1.1
0
0 = no, heat pump not blocked
1 = yes, heat pump can be blocked
P129P129
Bivalent
Minimum control percentage of the
boiler during on/o operation.
(relates to P127)
10 5% to 100%
P130P130
Defrosting Activating the boiler during defrosting. 1
0 = always activate the boiler when
defrosting.
1 = only activate the boiler below a certain
minimum temperature (P131).
2 = never activate the boiler.
P131P131
Defrosting
Setting minimum supply temperature
when defrosting (see P130=1).
15 ºC 5 ºC to 30 ºC.
P140P140
Bivalent
Setting electricity rate per kWh (high
rate).
0 0 to 9999 £/KWh.
P142P142
Bivalent
Setting electricity rate per kWh (low or
o-peak rate).
0 0 to 9999 £/KWh.
P144P144
Bivalent Setting rate per m gas 0 0 to 9999 £/m
P146P146
Bivalent
Setting CO emissions in grams per
KWh.
0 0 to 9999 g/KWh.
P165P165
Heat pump
Setting degree minutes for heating.
This aects when the heat pump starts
and stops (a higher value means fewer
activation changes).
0
0 = adaptive mode (adjusts itself)
1 to 42 degree minutes
(increments of 10 degree min.)
P167P167
Heat pump
Setting compressor reduction
percentage during Silent mode
(if P172=2)
50 20 to 100%
P171P171
Heat pump
Setting the external temperature value
(Silent mode deactivated below this
external temperature).
-20 ºC -20 ºC to 20 ºC.
P172P172
Heat pump
Activation/deactivation of Silent
mode.
0
0 = o
1 = on (fixed, non-adjustable reduction of
5 dB)
2 = a maximum percentage set by
the user (adjustable using P167)
P175P175
Heat pump
Setting whether the crankcase heater
remains hot.
1
0 = never (only when compressor starts)
1 = maximum of 24 hours
2 = always
P176P176
Heat pump
This setting determines if or when the
boiler will become involved in heating
for the crankcase heater.
1
0 = never
1 = automatic (delay time determined
based on P113, P114, P115 and P116)
2 = always
P180P180
CH comfort Setting the CH timed program. 0
0 = Comfort mode
1 = Eco mode
P181P181
CH comfort
Setting the dierence in room
temperature and heating threshold.
3 0 ºC to 15 ºC.