Example (Natural gas G20)
During maximum output a CO
2
(H) value
of 9.0 % has been measured. In this case
the CO
2
(L) value at minimum output
must be 8.7 ± 0.1 % (= 0.5x CO
2
(H) + 4.2)
as stated in the table 4 and 5. When
measuring the gas-air ratio at minimum
output (L) and the value is out of this
range then it must be adjusted, as
described in §9.10.3
IMPORTANT
The gas air control is correctly set if the
measured value at minimum output falls
within the indicated upper and lower
limits. Adjustment of the gas air control is
not necessary in this case. The setting at
minimum output must be adjusted using
the method described in §9.10.3 if the
measured value is outside the indicated
limits.
F. Reattach the room sealed cover and tighten the 2 screws by
hand.
Check the CO value at minimum output. The maximum
allowed CO measurement value is 160ppm.
G. Switch the boiler to maximum output. To do this, hold
the Service symbol and at the same time tap the Plus
symbol twice until the capital letter HH appears on the
right display. Check the CO value at maximum output. The
maximum allowed CO measurement value is 160ppm.
H. Switch o the boiler.
I. Remove the probe of the flue gas analyser from the flue gas
sampling point and carefully replace the cap on the adapter
above the boiler.
J. Switch on the boiler again.
K. Check the gas integrity of the flue gas sampling point.
L. Carry out a flue integrity test via the air sampling point on