6.4 Mount the appliance
1. Unpack the appliance.
2. Check the content of the packaging. This consists of:-
• Appliance (A)
• Mounting strip (B)
• Siphon cup (C)
• Flexible hose (D)
• Isolation valves
• Installation instructions
• Warranty card
3. Check the appliance for any damage: report damage to the supplier immediately.
1. Check when using a connection kit whether the compression rings are straight in the
connectors.
2. Place the appliance: slide it top-down over the mounting strip.
3. The flexible tube from the condensate siphon should be inserted into an open waste
pipe of not less than 32 mm diameter. If connected to a soil pipe or waste system,
the waste pipe must include a trap (similar to arrangement for washing machine).
4. Tighten the compression fittings.
5. Mount the air supply and the flue discharge.
6. Mount the siphon cup (C) to the siphon connection at the bottom side of the boiler.
Make sure the O-ring is placed correctly in the cup.
7. When needed the condensate outlet (behind the cup) can be extended using the
flexible hose that has been delivered together with the boiler.
8. Fill the internal siphon by removing the hose coming from the PRV.
Make sure the hose is placed again afterwards.