Short press to change the current parameters for the
selected menu option, enter the submenu, or confirm
submenu changes.
Long press to save any changes and exit to the home
screen.
Short press the Power
Button to return to the previous menu
without saving.
After 15 seconds of inactivity, the menu will automatically close
and the interface will return to the home screen. Changes are
NOT saved automatically (except changes to toggle on / o
menu items, such as Ultra-clear and Wi-Fi).
Upon exiting from the main menu, the cursor location is stored
for a single working session (until the TH50CV2 is turned o).
After restarting the TH50CV2 and entering the menu, the cursor
position will be at the first menu item.
16. ZEROING THE BOLT TH50CV2
BOLT TH50CV2 features a “freeze” zeroing method. To zero the
TH50CV2:
1. Set a suitable target at the desired zero distance.
2. Confirm that the rifle is empty, safe, and pointed in a safe
direction, with no ammunition near the weapon.
3. Adjust the image and device settings following the steps in
the Quick Start Guide on page8, if you have not done so
already.
4. Select the zeroing profile, A, B, or C. See Main Menu > Zeroing
Profile on page33.
5. Based on the distance to the target you wish to zero, select
a preset zero distance, OR customize one of the preset zero
distances to match. The TH50CV2 supports custom zeroing
distances of 1to999 meters or 1to999 yards. See Reset
Zeroing Distance Menu on page34.
6. Ensure a stable platform and natural shooting position is
achieved behind the rifle.
7. Load ammunition, aim, and take one good shot at the target.
8. Make your rifle safe and observe the location of impact on the
target.
9. If the point of impact does not match the point of aim (the center
of the reticle), adjust the X/Y position of the reticle. See Reset
Zeroing Distance Menu > Reticle Zeroing on page34.
10. In the submenu for the selected zero distance, center the reticle
on the aiming point and long press the Photo
and Palette
Buttons at the same time to freeze the image. The image
freeze
icon appears at the bottom of the screen.
11. Select the axis (X or Y) along which to move the reticle by short
pressing the Control Turret to toggle between X and Y.
12. Adjust the X/Y position of the reticle until the reticle matches the
point of impact.
a. Rotate the Control Turret counterclockwise to move in the
positive direction: X=Right and Y=Up.
b. Rotate the Control Turret clockwise to move in the negative
direction: X=Left and Y=Down.
c. Upon moving the reticle, a white dot appears onscreen,
representing the original position of the reticle.
13. Long press the Control Turret to save the reticle position.
14. Take a confirmation shot—the point of impact should now match
the point of aim. If not, adjust the X/Y position of the reticle
again.
For detailed Zeroing instructions, please see Reset Zeroing Distance
Menu > Reticle Zeroing on page34.
17. NON-UNIFORMITY CORRECTION
A non-uniformity correction (NUC) allows a thermal imager’s sensors
to correct its pixels and eliminate any image defects caused by pixel
drift. A NUC will be performed automatically each time the BOLT
TH50CV2 is powered on.
The TH50CV2 has three NUC modes, automatic(A), manual(M), and
background(B). The selected NUC mode (A, M, or B) appears in the
top status bar. For instructions on setting the NUC mode in the main
menu, see Main Menu > Calibration on page37.
Automatic Mode
In automatic mode (A), the TH50CV2 will perform a NUC
automatically according to the internal software algorithm. There
is no need to close the objective lens cap(15) as the TH50CV2’s
internal shutter covers the sensor.
A countdown timer will appear in the top status bar instead of the
calibration mode when 5seconds remain until an automatic NUC is
performed. Short press the Power
Button before the countdown
concludes to cancel the automatic NUC. The timer will appear
only after the microbolometer temperature has stabilized—after
approximately 10 minutes of continuous operation of the TH50CV2.
NOTE: A manual NUC (see below) may be performed at any time
while in Automatic(A) mode.