Manually Enter Standby Mode 
The user may enter standby mode manually at any time.
1. From the home screen, long press the Power
Button to bring 
up the shutdown/standby screen. 
2. Release the Power
Button before the 3-second countdown 
finishes to enter standby. 
Adjusting the Focus
ADJUSTING THE DIOPTER/EYEPIECE
1. Rotate the eyepiece diopter adjustment ring (2) at the rear of the 
rifle scope right or left until the onscreen user interface is clear. 
2. Look closely to ensure all icons, the status bars at the top and 
bottom of the screen, and the reticle appear sharp and in focus. 
No additional diopter adjustments are required unless the user 
wishes to make changes. 
NOTES: 
• After this initial adjustment, there is no need to rotate the 
eyepiece adjustment ring (2) for long distances or any other 
conditions. 
• If necessary during standard use, you may rotate the objective 
lens focus ring(14) to adjust fine focus on the target object being 
observed. See Focusing the Objective Lens below.
FOCUSING THE OBJECTIVE LENS 
To adjust the focus on the target object:
1. Rotate the objective lens focus ring (14) left or right to focus on 
the target object being observed. 
NOTE:  Re-adjusting the focus will be needed if the distance to 
your target changes.
Activating / Deactivating the Reticle
The reticle may be inactive when the TH50CV2 is powered on for 
the first time. To activate the reticle, or to deactivate it at a later time: 
1. From the home screen, press and hold the Photo
 and
Brightness 
Buttons at the same time for at least 15 seconds.
Status Bar Overview
The status bars at the top and bottom of the screen show information 
on the operating status of the BOLT TH50CV2:
14:35
3.5×
6 m i n
A
10
1 32 4
11 12 13 14
5
6
7
89
1    Color Palette:  Shows the set color palette, white hot  , black 
hot 
, red hot  , color  , or highlight  . White hot is the 
default.
2    Non-Uniformity Correction (NUC) Mode:  Shows the 
non-uniformity correction (NUC) 
 icon and selected mode, 
automatic (A), manual (M), and background (B). Automatic is 
selected by default. Acountdown timer will appear instead of 
the NUC mode when 5seconds remain until an automatic NUC.
3    Standby:  Shows the standby 
 icon and status, 2min, 4min, 
6min, or o. Standby is o by default.
4    Time:  Shows the current time in 24-hour format. 
5    Digital Compass:  Displays when the compass is turned on. 
Compass is o by default. 
6    Gravity Sensor:  The two gravity sensor indicators (tilt and pitch) 
display when the gravity sensor is turned on. The gravity sensor 
is o by default. 
7    Battery Charging:  The battery charging 
 icon appears above 
the battery status indicator for the built-in battery pack when 
the TH50CV2 is connected to an external power source.
8    Built-in Battery Status Indicator:  Shows the battery status 
of the built-in battery pack. When the TH50CV2 is receiving 
power from the battery pack, the battery indicator is in color; 
when inactive, the battery indicator is gray. 
9    Auxiliary Battery Status Indicator:  Shows the battery status 
of the rechargeable auxiliary battery. When the TH50CV2 is 
receiving power from the auxiliary battery, the battery indicator 
is in color; when inactive, the battery indicator is gray. 