VMB301 Condition monitoring sensor with CANopen interface
34
11.1 Object directory (machine utilisation / load cycle counter)
Index
Sub-in-
dex
Name
(Object)
Type Access Default value
PDO
Mapping
capability
Selection
option
0x4004 0x01 Limit value -
Load cycle counter 1
r32 rw 0.004 m/s -
0x02 Limit value -
Load cycle counter 2
r32 rw 0.012 m/s -
0x03 Load cycle counter 1 u32 ro -
0x04 Load cycle counter 2 u32 ro -
0x05 Reset
Load cycle counter 1
u32 wo - 1: Reset
0x06 Reset
Load cycle counter 2
u32 wo - 1: Reset
0x07 Limit value - machine
switch-on operations
r32 rw 0.004 m/s -
0x08 Counter - machine
switch-on operations
u32 ro -
0x09 Reset machine switch-on
operations
u8 wo - 1: Reset
0x2051 0x00 Selection of the measur-
ing axis for the speed pa-
rameters (v-RMS)
u8 rw 7: (xyz axis) - 1:
(x axis)
2:
(y axis)
3:
(xy axis)
4:
(z axis)
5:
(xz axis)
6:
(yz axis)
7:
(xyz axis)