VMB301 Condition monitoring sensor with CANopen interface
22
Index Subindex
Name
(object)
Type Access Default value
PDO
Mapping
capability
Save object
value
0x04 Raw data
read-out
DO ro - -
0x4004 Machine utilisation / load cycle
counter
0x01 Limit
Load cycle coun-
ter 1
r32 rw 0.004 m/s - Yes
0x02 Limit
Load cycle coun-
ter 2
r32 rw 0.012 m/s - Yes
0x03 Load cycle coun-
ter 1
u32 ro -
0x04 Load cycle coun-
ter 2
u32 ro -
0x05 Reset
Load cycle coun-
ter 1
u8 wo 1 -
0x06 Reset
Load cycle coun-
ter 2
u8 wo 1 -
0x07 Limit value: ma-
chine switch-on
operations
r32 rw 0.004 m/s - Yes
0x08 Machine switch-
on operations
u32 ro -
0x09 Reset
Machine switch-
on operations
u8 wo 1 -
0x5c00 Maximum value memory: displace-
ment
(d-Peak2Peak)
0x01 Maximum value
memory
displacement
(d-Peak2Peak)
r32 ro -
0x02 Reset maximum
value memory:
displacement
(d-Peak2Peak)
u8 wo 1 -
0x5sc01 Maximum value memory: fatigue
(v-RMS)
0x01 Maximum value
memory
displacement
(d-Peak2Peak)
r32 ro -
0x02 Reset maximum
value memory:
displacement
(d-Peak2Peak)
u8 wo 1 -
0x5sc01 Maximum value memory: fatigue
(v-RMS)
0x01 Maximum value
memory: fatigue
(v-RMS)
r32 ro -
0x02 Reset maximum
value memory: fa-
tigue
(v-RMS)
u8 wo 1 -