Ultrasonic flow meter SU2x5x SU6x5x SU7x5x SU8x5x SU9x5x
9
5 Installation
CAUTION
If the medium temperature is above 50 °C (122 °F), parts of the housing can increase in
temperature to over 65 °C (149 °F).
w Risk of burns.
u Protect the housing against contact with flammable substances and unintentional
contact.
ATTENTION
No functional earthing when installed in an ungrounded pipe system (e.g. plastic pipes).
w Deficient operating function.
u Ground the device. Ground brackets for the M12 connector are available as accessories,
see documentation.ifm.com.
After installation, air bubbles in the system can affect the measurement.
u Rinse the system after installation for ventilation.
u Ensure that the system is free of pressure during installation.
u The rules and regulations for the installation and operation of compressed air equipment
must be observed.
5.1 Process connection
Using process adapters the unit can be adapted to different process connections.
Information about available accessories at documentation.ifm.com.
The optimum function is not ensured when using components from other manufacturers.
4
5a 5b
43 32 21 1
Fig.1: Process connection
1: Pipe 2: Adapter
3: Seal (only devices with G-thread) 4: Sensor thread
5a: Hexagonal 5b: Hexagonal (only SUx6x1)
u Grease the threads of the process connection, adapter and sensor. Use a lubricating paste which
is suitable and approved for the application.
u Screw the adapter into the pipe.
u Place the seals and insert the device. Observe the direction of flow (Ò Flow direction/27).
u Screw the adapter to the sensor thread until it is hand-tight.