RM900S RM901S RM902S RM903S Encoder (SR) with CANopen interface
24
8.3 Abbreviations and definitions
EMC Electromagnetic compatibility
ESD
Electrostatic discharge
Fault exclusion Compromise between the technical safety requirements and the theoretical possi-
bility of a fault occurring.
Functional safety Part of overall plant safety that depends on the correct functioning of safety-related
systems for risk reduction. Functional safety is ensured if each safety function is
executed as specified.
IEC International Electrotechnical Commission
ISO International Standard Organisation
PL Performance level:
Discrete level that specifies the capability of safety-related parts of a controller to
perform a safety function under predictable conditions.
SIL Safety integrity level Four discrete levels (SIL1 to SIL4). The higher the SIL of a
safety-related system, the lower the probability that the system will not be able to
carry out the required safety functions.
SR Safety Related
Ag PL d The standard defines the Agricultural Performance Levels (AgPL) QM, a–e. AgPL
a to e correspond to the Performance Levels (PL) a to e as defined in ISO 13849.
MPL d This part of ISO 19014 specifies general principles for the development and as-
sessment of the attained machine performance level (MPL a–e) of safety control
systems (SCS).